Home > 제품 상세보기
DESCRIPTION
Product name: Battery testing system CT-4008T-5V12A-S1
SPECIFICATION
Input AC |
AC 220V/110V ±10% / 50Hz |
||||
Input power |
826 W |
||||
Resolution |
AD:16bit; DA:16bit |
||||
Input impedance |
≥1MΩ |
||||
Voltage |
CV output range |
25mV~5V |
|||
Min discharge voltage |
2V for universal holder,2.5V for 2m cable |
||||
Accuracy |
± 0.05% FS |
||||
Stability |
± 0.05% FS |
||||
Current |
Output range/channel |
Range1: 5mA-1A; Range2: 1A-6A; Range3: 6A-12A |
|||
Accuracy |
± 0.05% FS |
||||
CV cut-off current |
Range1: 2mA; Range2: 12mA;Range3: 24mA |
||||
Stability |
± 0.05% FS |
||||
Power |
Output power/channel |
60W |
|||
Stability |
± 0.1% FS |
||||
Time |
Current response time |
<1ms (10% FS~90% FS) |
|||
Working step time |
≤(365*24)h/step Timeformat-00:00:00.000(h, m, s, ms) |
||||
Data record |
Data record conditions |
Min data record interval: 100ms |
|||
Min voltage change: 10mV |
|||||
Min current change: 2mA; 12mA; 24mA |
|||||
Frequency |
10Hz |
||||
Charge |
Charge modes |
CC, CV, CCCV, CP |
|||
Cut-off condition |
Voltage, Current, Time, Capacity, Energy, -△V |
||||
Discharge |
Discharge modes |
CC, CV, CCCV, CP, CR |
|||
Cut-off condition |
Voltage, Current, Time, Capacity, Energy |
||||
Pulse |
Charge |
CC, CP |
|||
Discharge |
CC, CP |
||||
Min pulse width |
500ms |
||||
Pulse counts |
Up to 32 |
||||
Chg and Dschg switch |
Supported |
||||
Cut-off condition |
Voltage, Time |
||||
DCIR |
Calculated DCIR values available in BTSDA |
||||
Cycle |
Max cycles |
65535 |
|||
Max steps |
254 |
||||
Cycle nest |
3 |
||||
Protection |
Safety protection |
Power-failure data protection |
|||
Offline operation mode |
|||||
User-defined protection conditions, such as upper and lower current/voltage, delay time, temperature, etc. |
|||||
Channels feature |
Independent pairs of closed loop for constant |
||||
Channels control mode |
Independent control |
||||
Data acquisition method |
Kelvin connection |
||||
Noise |
<85dB |
||||
Database |
MySQL |
||||
Communication |
TCP/IP |
||||
Operating system |
Windows 7/8/10 64bit |
||||
Data export |
EXCEL, TXT, CSV, PDF, Plot/Graph |
||||
Min. disk drive |
500GB |
||||
Communication port |
Ethernet port |
||||
Leak Current |
<5μA |
||||
Channels per unit |
8 |
||||
Operation and storage environment requirement |
|||||
Operation environment temperature |
0℃~40℃ (When the temperature is 25±10℃, the accuracy offset caused by temperature is less than 50ppm/℃) |
||||
Storage environment temperature |
-10℃~50℃ |
||||
Operation environment humidity |
≤70% RH(no moisture condensation) |
||||
Storage environment humidity |
≤80% RH(no moisture condensation) |
||||
Clamps and dimensions |
|||||
Tester pictures |
|
||||
Clamps pictures |
|
|
|
|
|
Universal holder |
Alligator |
Polymer |
Ring connector |
||
Pictures just for reference |
|||||
Dimensions (W*D*H)(mm) |
3U19", 483*563*130(S1) / 483*518*130(204n) |
||||
Warranty |
One year limited warranty with lifetime support |